Patriot - Troubleshooting Guide

Patriot - Troubleshooting Guide

!!! IMPORTANT FIRST STEP !!!
First thing to verify is that no monitored entrapment devices are creating the problem.
  1. Press the Open/Close button on the control board. If gate does not operate proceed to step 2.
  2. Press the Type D S4 push button and hold to operate the gate.
  3. If gate operates while pressing the S4 button then a monitored device is preventing normal operation.
  4. If control board clicks and gate does not operate the battery needs to be load tested, replace or charge as necessary
  5. Identify monitored devices connected and check for proper operation.
Verify monitored entrapment device switches are set correctly. See installing monitored entrapment devices section of the manual. Patriot Gate Opener Manuals
  1. Patriot - When Pressing the LED Indicator D5, D12 and D14 are ON
  2. Patriot - Secondary Entrapment Siren Beeps 3 Times Pauses 5 Seconds Repeats
  3. Patriot - S5 When Pressed and Held Operates the Gate, but Open/Close Command Does Not
  4. Patriot - Gate Will Not Operate
  5. Patriot - Gate Will Not Operate and Battery Status is Good
  6. Patriot - Gate Opens Using Transmitter, But Will Not Close Using Transmitter
  7. Patriot - Wiring Harness 20 Amp Fuse Blows When Harness is Connected to the Battery
  8. Patriot - Gate Begins to Open or Close but Stops and Reverses After a Couple of Seconds
  9. Patriot - My Gate Will Not Automatically Close
  10. Patriot - Single Gate Opens or Closes, then Immediately Reverses Direction
  11. Patriot - Dual Gate Opens or Closes then Immediately Reverses Direction
  12. Patriot - Gate Only Operates When the “LED INDICATOR” is Pressed
  13. Patriot - Gate Fully Open and Close Stop Positions are Changing (not consistent)