Ranger HD - Troubleshooting Guide

Ranger HD - Troubleshooting Guide

!!! IMPORTANT FIRST STEP !!!
First thing to verify is that no monitored entrapment devices are creating the problem.
  1. Press the Open/Close button on the control board. If gate does not operate proceed to step 2.
  2. Press the Type D S4 push button and hold to operate the gate.
  3. If gate operates while pressing the S4 button then a monitored device is preventing normal operation.
  4. If control board clicks and gate does not operate the battery needs to be load tested, replace or charge as necessary
  5. Identify monitored devices connected and check for proper operation.
Verify monitored entrapment device switches are set correctly. See installing monitored entrapment devices section of the manual. Ranger HD Gate Opener Manuals
  1. Ranger HD - Single Gate Will Not Operate
  2. Ranger HD - Dual Gate Will Not Operate
  3. Ranger HD - Single or Dual Gate Will Not Operate
  4. Ranger HD - Gate Will Not Automatically Close
  5. Ranger HD - Gate Begins to Open or Close but Stops and Reverses After a Couple of Seconds
  6. Ranger HD - Single Gate Opens or Closes Correctly, then Immediately Reverses Direction
  7. Ranger HD - Dual Gate Opens or Closes Correctly then Immediately Reverses Direction
  8. Ranger HD - Transmitter Will Not Operate the Gate
  9. Ranger HD - Gate Opens Using Transmitter, but Will Not Close Using Transmitter
  10. Ranger HD - Photo-eye Being Used for Vehicular Protection Will Not Reverse the Gate When Closing or Hold the Gate Open
  11. Ranger HD - Pressing the “RESET” Button Only, Causes the Gate to Operate
  12. Ranger HD - Battery Will Not Stay Charged
  13. Ranger HD - Wiring Harness 20 Amp Fuse Blows When Harness is Connected to the Battery