Ranger HD - Gate Opens Using Transmitter, but Will Not Close Using Transmitter

Ranger HD - Gate Opens Using Transmitter, but Will Not Close Using Transmitter

LCR Receiver Only
  1. The problem is most likely the programming of the LCR receiver (P2 relay is programmed to latch mode)
  2. On the Ranger control board locate press and hold the “LED Indicator” pushbutton.
  3. Look below the J2 terminal plug of the Ranger control board and note any LED’s that are on.
  4. If the “Free Exit/Open Input” LD2 is on then the receiver (P2) is programmed to latch mode.
  5. Go to “Resetting receiver P2 relay to momentary mode” section.
  6. If this does not correct the problem return to troubleshooting section 4 and perform steps 1-5.