Ranger HD - Pressing the “RESET” Button Only, Causes the Gate to Operate

Ranger HD - Pressing the “RESET” Button Only, Causes the Gate to Operate

  1. This problem is probably due to a bad receiver. First locate the “LED Indicator” push button on the Ranger control board. Then locate the “Push Button Input” LED located below the J2 terminal plug of the Ranger control board.
  2. Press the “LED Indicator” button and observe the “Push Button Input” LED. If the LED comes on then the receiver relay is stuck closed and needs to be repaired or replaced.
  3. If the “Push Button Input” LED does not come on, call the factory for further troubleshooting and return information.