Ranger HD - Dual Gate Opens or Closes Correctly then Immediately Reverses Direction
- Dual Gate opens or closes correctly then immediately reverses direction.
- Locate the SW1 switches on the Ranger control board. Switch 3 and 4 should be turned on for a dual gate, turn off switch 4. This will disable one gate.
- Operate the gate and verify that it stops in the correct position. If so then turn switch 4 back on and turn switch 3 off. Operate the other gate now and verify that it stops in the correct position. One or both may not stop in the correct position.
- Once the gate that needs adjustment is identified (possibly both) readjust limits to correct position.