Ranger HD - Gate Will Not Automatically Close
If SW1 switch 1 is on then the gate should automatically close from any position.
- Locate the “Open/Close Command “ push button. Press the button to verify that the gate will close. If gate closes correctly then proceed to the steps below.
- Verify that SW1 switch 1 is on. If not, turn it on and recheck gate operation. If gate remains open, continue with step 3.
- Locate the “LED Indicator” push button and depress and hold. While pushing the button inspect the LED indicators located on the control board (under the J2 Terminal Plug) and note which LED’s are on. If LD1, LD2, LD6 or LD7 are ON then remove the wire from J2 for that LED and cycle gate and verify auto close is working.
- If so the device wired to J2 pin 3, 9, 10 or 11 that was disconnected is bad.