Ranger HD - Single or Dual Gate Will Not Operate

Ranger HD - Single or Dual Gate Will Not Operate

Monitored Entrapment Devices Are Installed

Contact Edge with 10K Resistor Monitoring

  1. Verify that dip switch SW1 switch 10 (contact edge monitor) is ON pressed down on the right hand side.
  2. Press and hold the LED indicator on the control board.
  3. Verify the LD3 LED (Contact edge 2nd entrapment) located below the J2 plug is OFF.
  4. If ON then check wire connections from contact edge for proper connection.
  5. If wires are good then verify the contact edge has a 8.25k or 10k resistor installed. Verify by disconnecting and checking with meter.
  6. Activate the contact edge by depressing it and verify the LD3 LED is ON bright.
  7. If not, contact edge is bad.

Photo Eye N/C Contact Monitoring

  1. Verify that SW1 dip switch 10 is ON press down on the right hand side.
  2. Verify that dip switch SW1 switch 7 or 8 (photo eye monitor) is ON press down on the right hand side. Turn ON the ones being used.
  3. Turn dip switch SW1 3 and 4 OFF. Allows power to be applied to photo eye.
  4. Press and hold the LED indicator button located on the control board.
  5. Verify that LD4 or LD5 LED (Photo eye N/C) located below J2 on the control board is ON.
  6. If not verify alignment between photo eye transmitter and receiver. Correct if necessary.
  7. If not then check wire connection from photo eye for proper connection.
  8. If LD4 or LD5 are ON verify that the Led goes OFF when photo eye beam is broken.
  9. If LED does not turn OFF when beam is broken then photo eye is bad.