First thing to verify is that no monitored entrapment devices are creating the problem.
Press the Open/Close button on the control board. If gate does not operate proceed to step 2.
Press the S4 push button and hold to operate the gate.
If gate operates while pressing the S4 button then a monitored device is preventing normal operation. Proceed to step 5.
If gate does not operate while pressing the S4 push button, proceed to the troubleshooting step which describes your problem and installation.
Identify monitored devices connected and check for proper operation.
Verify monitored entrapment device switches are set correctly. See installing monitored entrapment devices section of the manual. Patriot RSL Gate Opener Manuals