Patriot RSL - Gate Opens or Closes Correctly, then Immediately Reverses Direction

Patriot RSL - Gate Opens or Closes Correctly, then Immediately Reverses Direction

  1. Gate is opening or closing to far identify the limit switch which is out of adjustment and adjust so that gate stops earlier. The limit switches are located on the limit plate assembly on top of the operator.
  2. If limit switches are adjusted correctly and gate is not stopping when switch is depressed verify limit switches and wires are good. Press the LED indicator and observe the retract and extend limit lights. Press the limit switch closest to the gate (white wire connected to it) and verify the extend limit light comes ON. Press the other limit switch ( orange wire connected to it) and verify the retract limit light comes ON. If either one does not work verify wires are good if so replace limit switch.