Patriot RSL
Patriot RSL - Verifying Charge System is Operating Correctly
The one test that will verify that the charger and Power source is working properly is a DC current reading between the charger and battery. Disconnect the black lead from the battery. Set multi meter up to read DC current. Connect red meter lead to ...
Patriot RSL - Battery Will Not Stay Charged
The most common reason for this type of problem is a bad battery. It is highly recommended that the battery be load tested at a battery store to verify that it is good. The load test is the only sure way to know if we have a good battery. If the ...
PAtriot RSL - Gate Open and Close Stop Position is Changing (not consistent)
Limit switch lever has been bent and is not contacting limit cam nut at the correct location. The limit cam nut leading edge should depress the limit switch lever well before reaching the peak of the limit switch lever. Adjust limit switch lever ...
Patriot RSL - Gate Opens Using Transmitter, but Will Not Close Using Transmitter
LCR Receiver Only The problem is most likely the programming of the LCR receiver (P2 relay is programmed to latch mode) On the Patriot control board locate press and hold the “LED Indicator” push button. Look in the lower left corner of the Patriot ...
Patriot RSL - Pressing the “RESET” Button Only, Causes the Gate to Operate
This problem is probably due to a bad receiver. First locate the “LED Indicator” push button on the Patriot control board. Then locate the “Push Button Input” LED located in the lower left corner of the Patriot control board. Press the “LED ...
Patirot RSL - Photo-eye Being Used for Vehicular Protection Will Not Reverse the Gate When Closing or Hold the Gate Open
The first thing to check is the accessory wiring. The accessory needs power (+12 vdc) wired to battery positive terminal or to J2 pin 1 on the Patriot control board. It also needs ground, which can be wired to the battery or to J2 pin 2 or 7 on the ...
Patriot RSL - Transmitter Will Not Open the Gate
LCR Radio Equipment Only Open the control box and locate the Patriot control board. Locate the “LED Indicator” push button and the “Push Button Input” LED. Push and hold the “LED indicator” push button, then press the transmitter button and observe ...
Patriot RSL - Control Board 15 Amp Fuse Blows When Open / Close Command is Given
Fuses blow primarily for one reason, the gate cannot move. Causes might be something keeping the gate from moving, the gate is trying to move in the wrong direction due to incorrect limit switch setting or there might be a wiring problem. A wiring ...
Patriot RSL - Gate Opens or Closes Correctly, then Immediately Reverses Direction
Gate is opening or closing to far identify the limit switch which is out of adjustment and adjust so that gate stops earlier. The limit switches are located on the limit plate assembly on top of the operator. If limit switches are adjusted correctly ...
Patriot RSL - Gate Begins to Open or Close but Stops and Reverses After a Couple of Seconds
Remove control box cover and locate the Patriot control board. Locate the sensitivity adjustment (see page 26) potentiometer located on the control board. The white center is adjustable and needs to be turned in a clockwise direction to increase ...
Patriot RSL - My Gate Will Not Automatically Close
If DS1 switch 1 is on and switch 2 is off then the gate should automatically close from any position. If switch 2 is also on the gate will only automatically close if the “retract limit” for right hand installation or “extend limit” for left hand ...
Patriot RSL - My Gate Opens / Closes Slowly
When the gate is running slow the reason is most likely low battery voltage. Two things need to be considered. Battery condition (replace or charge) and what caused the battery to become discharged. Bad motor in actuator is also possible but not ...
Patriot RSL - Emergency Release Knob Cannot Be Pulled
If the emergency release knob cannot be pulled, first verify that it is not already pulled by trying to roll the gate. If gate will not move, try to pull the emergency release knob while agitating the gate (shake gate in direction of travel). ...
Patriot RSL - My Gate Will Not Operate, Monitored Entrapment Devices are Installed
Contact Edge with 10K Resistor Monitoring Verify that dip switch DS2 switch 4 (contact edge monitor) is ON pressed down on the right hand side. Press and hold the LED indicator on the control board. Verify the D5 LED (Contact edge 2nd entrapment) ...
Patriot RSL - My Single Gate Will Not Operate
Remove control box cover locate the “Open/Close Command” push button and press it to operate the gate. Press the “Reset” push button located above the “Open/Close Command” button, then push the “Open/Close command” push button to operate the gate. ...
Patriot RSL - Troubleshooting Guide
!!! IMPORTANT FIRST STEP !!! First thing to verify is that no monitored entrapment devices are creating the problem. Press the Open/Close button on the control board. If gate does not operate proceed to step 2. Press the S4 push button and hold to ...