!!! IMPORTANT FIRST STEP !!! First thing to verify is that no monitored entrapment devices are creating the problem. Press the Open/Close button on the control board. If gate does not operate proceed to step 2. Press the Type D S4 push button and ...
Verify that the open and close positions are both changing randomly, before following these steps. Remove the five 5/16 bolts from the back of the actuator to expose the limit assembly. Loosen the 4 screws that hold the limit assembly in place ...
An accessory wiring problem, gate 2 cable spices are wet or a bad control board can cause this, this problem can be intermittent and possibly take a little patience in locating the problem. Using a DC volt meter take voltage readings on the following ...
Verify that the gates are not crossing the path of the photo eye. This is most likely caused by an incorrect limit switch adjustment. First determine which gate is in need of adjustment. Locate the DS1 switches on the Patriot control board. Switch 3 ...
Verify that the gates are not crossing the path of the photo eye. This is most likely caused by an incorrect limit switch adjustment. The limit switch adjustments are located on the bottom of the actuator motor housing, behind the removable rubber ...
If DS1 switch 1 is on and switch 2 is off then the gate should automatically close from any position. If switch 2 is also on the gate will only automatically close if the “Retract Limit” LED (both “open limit” LED’s for dual gate) is on. Locate the ...
Remove control box cover and locate the Patriot control board. Locate the sensitivity adjustment (see page 39) potentiometer located on the control board. The white center is adjustable and needs to be turned in a clockwise direction to increase ...
LCR Receiver Only The problem is most likely the programming of the LCR receiver (transmitter button is programmed to the P2 channel). On the Patriot control board locate the “LED Indicator” pushbutton. Press and hold. Look in the lower left corner ...
Press the S5 button and hold. If gate operates a monitored entrapment device is not working or improperly setup. Identify the entrapment device installed (there could be more than 1) and verify it is operating correctly. If no contact edges are ...
Press and hold the LED indicator push button. Look at the battery status LED located to the right of the LED push button. If light is OFF battery has failed remove battery and have it load tested.
The S5 push button requires constant pressure for gate operation. This button bypasses the entrapment protection requirement as you are the safety device. Releasing the button will stop gate. The LED indicator button may show you what the issue is. ...
This indicates the battery voltage has fallen below 10.5 vdc during operation. Press the LED indicator and observe the D12 LED it should be flashing indicating the battery needs to be load tested and charging system checked for proper operation.
D12 - battery status indicator – On indicates battery is Good. D5 - Monitored contact edge #1 – This LED monitors for the presence of a contact edge with either 8.25k or 10k resistor installed. If not present the LED will be ON. If installed LED ...