Ranger 500 - Single Gate Will Not Operate
- Open the control box cover locate the “Open/Close Command” push button and press it to operate the gate.
- Press the “Reset” push button located above the “Open/Close Command” button, then push the “Open/Close command” push button to operate the gate.
- Press and hold the “LED Indicator” push button and observe all of the red LED’s
- If any of the LED’s below the J2 terminal plug on the control board are on then this must be corrected. These lights correspond to the J2 accessory input terminals.
- Identify the light that comes ON and then the J2 terminal number it is associated with.
- Locate the accessory, which is connected to that J2 terminal number.
- Disconnect the accessory wire from that J2 terminal and verify gate operation.
- Call the factory for more information if the above steps have not worked.