Ranger 500 - Dual Gate Opens or Closes Correctly then Immediately Reverses Direction

Ranger 500 - Dual Gate Opens or Closes Correctly then Immediately Reverses Direction

  1. Dual Gate opens or closes correctly then immediately reverses direction.
  2. Locate the SW1 switches on the Ranger control board. Switch 3 and 4 should be turned on for a dual gate, turn off switch 4. This will disable one gate.
  3. Operate the gate and verify that it stops in the correct position. If so then turn switch 4 back on and turn switch 3 off. Operate the other gate now and verify that it stops in the correct position. One or both may not stop in the correct position.
  4. Once the gate that needs adjustment is identified (possibly both) readjust limits to correct position.