How to Wire a CP4 Free Exit Device by Cartell
Overview
In this article you will learn how to wire a CP4 Free Exit Device by Cartell to your USAutomatic gate opener control board. There will also be instructions for wiring other brands. These instructions apply to all current USAutomatic gate openers.
Applies to Part Number(s)
- 070305
What You Need
- A small flat-head screwdriver.
Procedure
Wiring the CP4 Free Exit Device by Cartell
Use the chart below to determine where to connect each wire.
J2 Terminal Block #
| CP4 Wire Color
|
#1
| Red
|
#2 or #7
| Black
|
#2 or #7 | White
|
#9
| Blue
|
Not Used | Yellow (not used) |
- Disconnect the J2 terminal from the control board.
- Unscrew the terminals listed above.
- Insert the wires according to the chart above and tighten the screws.
- Plug the J2 terminal back into the control board.